Cunliffe south elevation facework panel complete- CVA comments to follow
Cunliffe hit and miss panel complete- CVA comments to follow
Falsework to G/L 1 where HCL modifications due to cover requirements on projecting reinforcement within cavity. HCL still to forward details of insulation to adapted detail- Action HCL
Bean LRC 1FL slab cast.
Bean Hall GFL
Seminar Stair- stepped wall cast awaiting precast elements
Reinforcement to 1FL dwarf wall Bean LRC
Reinforcement to 1FL Bean- caps required- Action HCL
Awaiting bridge falsework between Bean & Cunliffe
Reinforcement to Seminar stair stepped wall- awaiting pour
Refurbished Bean LRC GFL- CVA to confirm removal of tiles/ lining detail if not provided- CVA to check contract documents
1FL Cunliffe - blockwork underway
Cunliffe- falsework for new stair landings underway
Bean LRC- 1FL slab overview
Cunliffe G/L 1- ring bean demolition incorrect. Detail not as survey- CVA/ HRW to review
HCL check to coverage of rebar to 2FL slab- HCL to report back on investigation
Bean LRC GFL- brickwork over steel condemned- still in situ. HCL to confirm date for rebuild
Scaffold board missing- HCL to address immediately