Bean LRC 1st flr- as window has been set 1 brick too high there is now an issue with the grille and detail which deviate from CVA detail. Cill level to be 1m AFFL to ensure consistency with loose furniture. HCL to advise of revised grille size.
Ditto
Mould still very present 1FL Cunliffe- Action HCL
Ditto
Ditto
Clash between curtain wall and capping detail- to be addressed alongside fitting of pressed metal capping detail/ when pressed metal flashings applied- Action HCL
capping detail G/L 3/A- requires resin fill- also G/L 3/C. Flashings as H71 still to be applied. Action HCL
Cunliffe 2fl window reveal CU.ED.02.01 brickshield incorrect. Whole cut bricks with solid return required to corners. mitred/ glued slips unacceptable- Action HCL
Ditto
Cunliffe steel balustrade 2FL- 4 Bay revised drawing still required showing proposed remedials. No drawing received since comments of 09.06.15. Steel infill undersized- Action HCL
No temporary protection on any new doors or bespoke fitted joinery. Any damage will need to be made good/ items replaced- Action HCL
Ditto
Entire site strewn with rubbish making movement around site hazardous. Unacceptable- HCL to address- Action HCL
Framing underway to underside of arcade- black neoprene spacer required as per standard trespa spec H20/ 155A
Ditto
Insulation required to underside of soffit- link
Infill panels required above long precast beam to Bean Hall GFL. Coffers with ducts can be exempt as covered in perforated panelling. Fixing can be discussed/ sketched by CVA if required- Action HCL
Bean LRC lobby bulkhead soffit to be removed and set at correct height- Action HCL
Marshalls office- screen removed in error. HCL to reconstruct and fit - Action HCL
Making good of strair drylining required Bean LRC- Action HCL
Ditto acoustic/ fire protection. Stringer/ skirting to stair to be consistent with arris- Action HCL
Bean LRC perimeter ceiling detail 1FL- drylining around steel required locally within reveal- Action HCL
Librarians office- plasterboard/ plaster incomplete behind dado- Action HCL
Ditto
Ditto
cill/ EDPM to be addressed BE.EW.01.08- Action HCL
Plasterwork/ taping and jointing poor 1FL classrooms- Action HCL
Bean rooflights- airtightness detailing poor- Action HCL
Level of glazing to pyramid rooflights in relation to slate roof not as CVA details or Alucraft details C629-D112-4. HCL to advise
Airtightness details to be carried out internally prior to glazing- Action HCL
Awaiting grilles to plantroom enclosure. Upper level flashing to be addressed once installed- Action HCL
Trespa fitted to classroom block entry- no neoprene installed - Action HCL
Ditto- Action HCL