 Bean 1FL- recess to be extended as CVA DWG BE 07.1- current clash with blind installation

 Cunliffe 1FL CU 01.01- walls made good- awaiting decs.

 Cover detail Cunliffe West Stair- wide skirting detail to continue to external wall as agreed on site- to account for skewed stair geometry

 Cunliffe/ Bean interface- low level brickshield still incomplete and inaccessible as earlier CVA comments- HCL to advise

 Cunliffe East Stair 2FL- discrepancy from HRW detail as previously raised- HCL to provide detail as built and confirm compliance/ calcs for guarding requirements- Action HCL

Ditto

 Bean LRC overview

 Bean West Elevation GFL- Movement joint not full depth/ cut into brickwork. HCL to address- Action HCL
 Paving underway West Elevation Bean LRC

 Cunliffe 1FL walls/ ceiling interface to refurb- junction poor- HCL to address bead/ seal- Action HCL

 Bean LRC stair landing 1FL- conflict with Bower Fuller introduced bulkhead/ blind installation- HCL to address- Action HCL

 Bespoke joinery to link being used as contractors tool store/ unprotected and now damaged- HCL to advise on replacement/ remedial works where affected- Action HCL

 Cunliffe north elevation- awaiting completion of hit and miss vent panels

 Cunliffe- radiussed brickwork to bin sotre underway

 Pier to bin store- brickshield to Cunliffe still incomplete low level

Ditto- HCL to advise how brickshield will be completed where kerbs already installed- works out of sequence- Action HCL

 Cunliffe East elev- brickwork observation log now issued for completion- also remedials still to be completed- Action HCL

 Slurry mix applied to seminar stair wall- trim to fire-rated windows discussed. CVA to review with Jansen/ HCL to investigate powder coated profile as opening uneven- Action CVA/ HCL

 Bean refurb GFL- walls to be made good- Action HCL

 Mastic applied to link- awaiting trims/ cappings/ flashings

 Remedial works carried out to Cunliffe 1FL window heads but no proposal forwarded to CVA/ HRW for comment. HCL to forward for comment- Action HCL

 Bean stair refurb- HCL to investigate making good/ replacement of bricks as specified- alternatively aluminium PPC self coloured pressing- HCL to advise

 Render to old bean underway - bead position not as per CVA sketch.

 Paving detail- HCL to ensure gap consistent to perimeter

Paving underway West elevation Bean LRC
 

 Seminar stair ceiling- filling of holes/ making good required prior to decoration